Description
The OPTI UPS 6000VA/6000W (Uninterruptible Power Supply). DS6000I BT TO SS1250K33 Stabilizer Series is a High protection online double conversion UPS. They are the one of the best Interruptible Power Supply system in the market today. They can be used in places such as WORKSTATION, NETWORK & SERVER, PC & WORKSTATION, DATA CENTER & FACILITY, HOME & OFFICE, APPLIANCES, SOFTWARE and others. Contact us now and protect your precious equipment against power unreliable power supply or any kind of power issues.
Features
• True online double-conversion technology
• Wide input voltage range
• DSP and Three level technology
• Advanced PFC technology, input PF>99%
• Cold start
• Automatic battery charging on/off mode
• Lighting and surge protection
• LCD display
• Support generator connection
• Smart slot for mission critical applications
Applications
The Automatic Voltage Regulator can be use in situation such as:
- Factory Automation Process Control
- Factory Automation Equipment
- WORKSTATION
- NETWORK & SERVER
- PC & WORKSTATION
- DATA CENTER & FACILITY
- HOME APPLIANCES
- OFFICE APPLIANCES
- SOFTWARE
Specifications
MODEL
Model Name;DS6000I BT
Topology; True On-Line, Double Conversion / High Frequency
Output Waveform; Pure Sine Wave
Maximum Capacity; 6000VA/6000W
PHYSICAL
Dimension (W×H×L): 250×523×859mm
Net Weight: 97 kg
INPUT
Model Name: 208/220/230/240Vac , L1/L2+PE
Input Voltage Range: 110~300Vac
Input Voltage Range: ≥0.99
Input Frequency Range: 44Hz – 56Hz@ 50Hz / 54Hz – 66Hz@ 60Hz
Input Current Distortion THDi %: ≤ 3%@100%@Liner Load; ≤ 5%@100%@ Non-Liner Load
INPUT
Nominal Voltage: 208/220/230/240Vac , L1/L2+PE
Voltage Regulation: ± 1 %
Voltage Distortion: ≤ 2% THD, linear load, ≤ 6% THD, non-linear load
Synchronization Range: Settable, ±3Hz default
Output Frequency (Battery Mode): 50/60±0.1 Hz
Efficiency: Line mode with battery full charged 93%, ECO mode 98%, Battery mode 92%.Overload Capacity Overload Capacity (Line Mode): 102%~105%: Transfer to bypass after 10 mins, 105%~125%: Transfer to bypass after 1 min, 125%~150%: Transfer to bypass after 10s, >150%: Transfer to bypass after 500ms.
Overload Capacity (Battery Mode): 102%~105%: Transfer to bypass after 10 mins, 105%~125%: Transfer to bypass after 1 min, 125%~150%: Transfer to bypass after 10s, >150%: Transfer to bypass after 500ms
Crest Ratio: 3:1
BATTERY
Configuration: 12V7Ah × 16pcs
DC Nominal Voltage: 196Vdc (240Vdc optional)
Charging Current: 1A (1-12A Settable)
INDICATOR & ALARM
Display: LCD & LED
Alarm:
Bat. Mode; Sounding once per 4 seconds.
Low Bat; Sounding once per 2 seconds.
Overload; Overload Sounding once per second
Overload; Overload Sounding once per second
Fault: Continuous beeping
INTERFACE
Standard: RS232 & USB
Optional: SNMP Card & Dry Contact
ENVIRONMENT
Operation Temperature: 0-40°C, no derating
Storage Temperature: 0-70°C
Relative Humidity: 0-95% non-condensing
Noise Level: Less than 50dB@ 1Meter
Operating Elevation: The altitude should not exceed 1000m,and the height above 1000m should bereduced to a maximum of 4000m.Refer to IEC62040